SmartDrop™ XF - Nano Spectrophotometer
SmartDrop™ XF - Nano Spectrophotometer

Productos - Equipamiento - Espectrofotómetros NanoDrop

SmartDrop™ XF - Nano Spectrophotometer

Ref. NS1020

SmartDrop™ Nano Spectrophotometers for Microvolume Analysis of DNA, RNA and Proteins


SmartDrop XF – Spectrophotometer + Fluorometer

 

The Accuris SmartDrop™ series of nano spectrophotometers provides quick and easy quantification of small samples. Utilizing a small sample volume eliminates the need for dilutions, providing more accurate results.

 

A full color, 7” touchscreen with icon-driven menus and preprogrammed protocols gets users up and running quickly. No external computer is required. Each unit features a quartz pedestal onto which a drop of sample is placed. The arm is lowered and the drop is stretched into a liquid column of specificed length for spectral analysis. DNA, RNA and protein concentrations and purity numbers are displayed in a matter of seconds.

 

The resulting data can be printed, saved in the SmartDrop’s™ onboard memory or exported via USB as an Excel file. All SmartDrop™ models include an integrated printer. For OD600 readings, each model includes a cuvette port and two optical glass cuvettes. Three SmartDrop models are available to meet a range of applications and budgets.

 

 

  • Full-spectrum absorbance scanning and calculations of 260/280 and 260/230 ratios
  • Long-life Xenon lamp with precision monochromator
  • Auto-ranging path lengths of 0.05mm, 0.2mm and 1.0mm
  • Detect up to 15,000ng/µl of dsDNA without dilution
  • Integrated fluorometer for sensitive quantitation of low concentration nucleic acids

This top of the line spectrophotometer can perform not only UV-Vis readings in the range of 200-800nm but also fluorescence readings. Like the SmartDrop™ X, the SmartDrop™ XF features predefined programs for nucleic acids, proteins, and various colorimetric assays. The patented, motorized system gently stretches the sample column and allows for three different path lengths, providing accurate readings of samples from 0.5 to 2.0µl without dilution.


The integrated fluorometer yields more accurate, sensitive and selective quantitation of nucleic acids. The blue light channel (460nm) is useful for detection of dyes such as PicoGreen and RiboGreen as well as GFP and fluorescein. UV, green and red channel models are available upon
request.

 

SPECIFICATIONS

 

Model SmartDrop L (NS1000) SmartDrop X (NS1010) SmartDrop XF (NS1020)
Display 7-inch touch screen 7-inch touch screen 7-inch touch screen
Minimum sample size 1.0µl – 2.0µl 0.5µl – 2.0µl 0.5µl – 2.0µl
Path length 0.5mm 0.2mm, 1.0mm 0.05mm, 0.2mm, 1.0mm
Light source UV LED Xenon Flash Lamp Xenon Flash Lamp
Detector UV Silicon Photocell 2048 Element Linear Silicon CCD Array 2048 Element Linear Silicon CCD Array
Wavelength 260, 280, & 600nm 200 – 800nm (1nm steps) 200 – 800nm (1nm steps)
Absorbance range 0.2 – 50 A (10mm equivalent) 0.04 – 90 A (10mm equivalent) 0.04 – 300 A (10mm equivalent)
Absorbance precision 0.005 A 0.003 A 0.003 A
Lower limit of detection dsDNA: 10ng/µl; BSA: 0.1 mg/ml dsDNA: 2ng/µl; BSA: 0.1mg/ml dsDNA: 2ng/µl ; BSA: 0.1mg/ml
Upper limit of detection dsDNA: 2,500ng/µl; BSA: 75.0 mg/ml dsDNA: 4,500ng/µl; BSA: 135mg/ml dsDNA: 15,000ng/µl; BSA: 360mg/ml
Detection time < 6 seconds < 5 seconds < 6 seconds
Communication ports USB for data export USB for data export USB for data export
Voltage input DC 24V, 2A DC 24V, 2A DC 24V, 2A
Power 25W 25W 25W
Dimensions (WxDxH) 8.2 x 11.0 x 7.3 in. /   20.8 x 28.0 x 18.6cm 8.3 x 10.6 x 7.2 in. / 21.0 x 26.8 x 18.1cm 8.2 x 12.6 x 7.3 in. / 20.8 x 32.0 x 18.6cm
Weight 3.6 kg / 7.9 lbs 2.8 kg / 6.2 lbs 3.6 kg / 7.9 lbs
Cuvette OD600 detection      
Absorbance range 0.0 – 4.0 A 0.0 – 4.0 A 0.0 – 4.0 A
Absorbance stability [0,3) ≤ 0.5%, [3,4) ≤ 2% [0,3) ≤ 0.5%, [3,4) ≤ 2% [0,3) ≤ 0.5%, [3,4) ≤ 2%
Absorbance repeatibility [0,3) ≤ 0.5%, [3,4) ≤ 2% [0,3) ≤ 0.5%, [3,4) ≤ 2% [0,3) ≤ 0.5%, [3,4) ≤ 2%
Absorbance precision [0,2) ≤ 0.005 A, [2,3) ≤ 1%, [3,4) ≤ 2% [0,2) ≤ 0.005 A, [2,3) ≤ 1%, [3,4) ≤ 2% [0,2) ≤ 0.005 A, [2,3) ≤ 1%, [3,4) ≤ 2%
Fluorescence detection      
Excitation/Emission N/A N/A 460 ± 20nm / 525-570nm
Sensitivity N/A N/A dsDNA: 0.5pg/µl
Linearity N/A N/A R² ≥ 0.995
Repeatability N/A N/A ≤ 1.5%
Stability N/A N/A ≤ 1.5%

 

 



List price

Consultar


Cantidad:

Menos
1
Más






VolverVolver


ZYMO RESEARCH BIOLINE STARLAB AZENTA BIOER Technology Benchmark Scientific GVS FILTER TECH IT-IS LIFESCIENCE AZURE BIOSYSTEMS IKA PRIMER DESIGN ADVANSTA VITL ECOGEN DNA Diagnostic Gilson Ritter ABDOS Life Sciences PANREAC APPLICHEM LIEBHERR OVAN CRUMA J.P. SELECTA COMECTA INTRON Biotechnology

Servicio Técnico

E-mail: sertec@ecogen.com

Certificado de Calidad
Ecogen garantiza su calidad
Ptge. Dos de Maig 1, 08041 Barcelona




Utilizamos cookies propias y de terceros para finalidades analíticas y técnicas, tratando datos necesarios para la elaboración de perfiles basados en tus hábitos de navegación. Puedes obtener más información y configurar tus preferencias desde 'Configuración de cookies'.

Configuración de cookies